In short
- Calibrate for each seed lot using the exact seed, treatment and roller you will plant.
- Rate equals catch divided by target; adjust by that percent and repeat the test.
- Cross-check tank use against acres covered after the first few passes.
Why calibrate every time
An air seeder meters seed by the turn of a roller, and how much seed falls per turn depends on the seed size, the shape, the treatment and even the humidity. A setting that was right for last year's wheat can be off by a good margin for this year's lot. Calibrating is cheap, and a miss runs across every acre. Always follow the calibration procedure in your manufacturer manual, since each machine handles roller selection, gates and shaft rotation differently. The method below is the general idea behind most of them.
Set up the machine
Fill the tank with the actual seed you plan to plant, not something similar. Pick the roller the manual recommends for that seed and rate. Check the roller for wear, trash and bridging. Set the gate or opening as the manual directs. Place the calibration tray or bags under the meter outlets, and make sure the fan is off or set as the manual says for the test. Write down the seed species, variety, lot number, and the treatment, because next year you will want to know what you did.
Work out the target
Start with the acres per hour. Width in feet times speed in miles per hour times 5,280 divided by 43,560 gives acres per hour. For a 40 foot machine at 5 miles per hour that is 40 times 5 times 5,280, or 1,056,000, divided by 43,560, which gives about 24.2 acres per hour. At a target of 60 pounds per acre, the machine has to meter about 1,454 pounds per hour, or about 24.2 pounds per minute. The numbers are simple once you write them out, so write them out.
Run the catch test
Many manuals call for turning the meter shaft a set number of revolutions by crank, or running the drive for a measured distance. A common version is a one tenth acre test. One tenth acre is 4,356 square feet. Divided by a 40 foot width, that is 108.9 feet of travel, and at 60 pounds per acre the machine should drop 6.0 pounds. Weigh the catch on a scale you trust and subtract the weight of the container. If your manual uses revolutions instead, the idea is the same: compare what fell to what the target says should fall.
Adjust and repeat
Suppose you caught 5.4 pounds when you wanted 6.0. Divide the target by the catch, which is 6.0 divided by 5.4, or about 1.11. You need roughly 11 percent more seed per turn, so adjust the setting that way and run the test again. Do not trust one pass. Run it at least twice and take the average, and if two runs differ much, look for a sticky roller, a bridged tank or a leaky seal. Re-check whenever you change seed lots, rollers or treatments.
Check it in the field
A catch test on a stationary machine does not show everything. After planting a short stretch, compare the tank drop to the acres covered. If you used 3.0 acres worth of seed on what the monitor says was 3.4 acres, the rate is a bit heavy, and you should stop and find out why. Also check wheel slip, tire pressure and the drive ratio, because worn tires change the calibration. Ask your seed dealer for the seed count per pound for the lot, and watch seeds per square foot behind the machine at emergence.
Record and repeat
Write each result on a card kept in the cab: seed, lot, roller, setting, speed, catch and date. Next season with the same crop you will start near the right answer instead of from scratch. If a hired operator runs the seeder, make the card part of the handoff. Ask the operator to report any change in seed, roller or tires. Seed treatments, fertilizer in the tank and a switch from wheat to peas all change how the meter behaves, so treat each one as a new calibration.
Find providers near you