A yield monitor is only as honest as its last calibration, and a few loads weighed on a certified scale will tell you whether to trust your maps.

Aerial, Drone & Precision Services3 min read684 words

In short

  • Weigh several loads at different flow rates on a certified scale.
  • Calibrate each crop separately and recheck moisture with the same meter.
  • Keep a log of factors and scale tickets for every harvest.

Why calibration matters

A yield monitor measures grain flow, moisture, and ground speed, and converts them into bushels per acre. If the flow sensor is off, every map from that combine is off by the same percentage. That error sneaks into hybrid comparisons, rent negotiations, and variable rate decisions. Many farmers run the monitor for years on factory settings and wonder why the totals do not match the elevator. A calibration service, or a careful do-it-yourself job, ties the monitor to a real scale. Follow your combine and monitor manual for the exact procedure, because brands differ.

The basic method

Calibration compares what the monitor says with what a scale says. Harvest a load at steady speed, then weigh it on a certified scale, such as an elevator scale or a good grain cart scale. Say the monitor records 1,000 bushels, but the scale ticket totals 1,040. The correction factor is 1,040 divided by 1,000, which is 1.04, so the monitor reads 4 percent low. Most monitors let you enter the actual weight and then adjust the factor for you. Do this with several loads, not one.

Calibrate across flow rates

Grain flow changes with speed and yield, and the sensor can respond differently at slow and fast rates. Good calibration uses loads at low, medium, and high flow rates, often by changing ground speed or header width. A single fast load gives you a number that fits fast conditions and misses the rest. Many manuals call for between three and five loads for a first calibration. Keep the settings steady during the run, and do not stop or unload mid-load. Record each load and the weights so you can see whether the factors agree.

Moisture and test weight

Yield is reported at a standard moisture, so the moisture sensor has to be right too. Take a sample from each load, check it with a trusted meter, and compare it to the monitor reading. Your elevator's meter and your own may differ a little, which is normal, so use the same one consistently. For test weight, follow the manual. Errors here carry into bushels per acre, because a bad moisture number shifts the corrected yield. If the difference is more than the manual allows, have a dealer check the sensor.

Mistakes that spoil data

The usual problems are an uncalibrated header height sensor, wrong header width entered, a dirty or worn paddle or sensor, and calibrating in one crop and using the setting in another. Each crop needs its own calibration. Also check the delay setting that matches yield to position, because a wrong delay smears the map. Clean the sensors before harvest, and calibrate again if you change the header, the hybrid moisture range, or the sensor. Do a quick check against scale tickets all season, since drift happens.

Hiring a calibration service

If you hire a dealer or consultant, ask which procedure they follow, how many loads they weigh, and what paperwork you receive. You want the factors, dates, and scale tickets saved. Ask whether they will also check and clean the sensors and verify the header settings. Ask about timing and cost, which vary by region and brand. Arrange it before harvest, since techs book up quickly. Keep a calibration log with the crop, date, and factor for each season, so you spot trends and trouble early.

A quick field check each season

Midway through harvest, weigh one more load and compare. If the factor has moved more than a couple of percent from your last calibration, find out why before you keep going. Check the sensor for crop buildup, confirm the header settings, and look at the elevator for wear. Write the result in your log with the field, crop, and date. Also compare your season total to your bin and elevator totals, which gives you a final reality check on the monitor over the whole harvest.